{"id":1359,"date":"2026-03-27T07:42:14","date_gmt":"2026-03-27T07:42:14","guid":{"rendered":"https:\/\/wow2000.com\/?post_type=wpkj_product&#038;p=1359"},"modified":"2026-08-19T01:08:45","modified_gmt":"2026-08-19T01:08:45","slug":"onduleur-de-pompe-solaire-hybride-055-kw-4-kw","status":"publish","type":"wpkj_product","link":"https:\/\/wow2000.com\/en\/products\/onduleur-de-pompe-solaire-hybride-055-kw-4-kw\/","title":{"rendered":"JNP-V5 Hybrid Solar Pump Inverters \u2013 0.55 to 4 kW"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"presentation\">JNP-V5 Series for 0.55 to 4 kW Solar Pumps<\/h2>\n\n\n<p>The <strong>JNP-V5<\/strong> series includes nine inverters that drive AC pumps from a PV array, with a grid or generator input available according to the configuration. The range covers motors from <strong>0.55 to 4 kW<\/strong>. Selection depends on motor phase, rated current, PV-array voltage, hydraulic duty, and the selected power-source mode.<\/p>\n\n\n<p><strong>Range:<\/strong> 9 models \u00b7 <strong>Published maximum PV input:<\/strong> 450 or 480 V DC \u00b7 <strong>AC input:<\/strong> single-phase 198\u2013265\/264 V AC \u00b7 <strong>Motor output:<\/strong> 220\/230 V AC single-phase or three-phase by model \u00b7 <strong>Protection:<\/strong> IP65 \u00b7 <strong>Last updated:<\/strong> August 19, 2026.<\/p>\n\n\n<h2 class=\"wp-block-heading\" id=\"modeles\">Nine-Model Selection Table<\/h2>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Model<\/th><th>PV max. \/ MPPT range<\/th><th>Maximum PV current<\/th><th>Maximum motor 1PH \/ 3PH<\/th><th>Maximum output current 1PH \/ 3PH<\/th><\/tr><tr><td>JNP550L-V5<\/td><td>450 V \/ 80\u2013400 V<\/td><td>15 A<\/td><td>0.55 \/ 0.55 kW<\/td><td>5 \/ 2.5 A<\/td><\/tr><tr><td>JNP750L-V5<\/td><td>450 V \/ 105\u2013400 V<\/td><td>15 A<\/td><td>0.75 \/ 0.75 kW<\/td><td>6 \/ 3.5 A<\/td><\/tr><tr><td>JNP1K1L-V5<\/td><td>450 V \/ 130\u2013400 V<\/td><td>15 A<\/td><td>1.1 \/ 1.1 kW<\/td><td>9 \/ 5.5 A<\/td><\/tr><tr><td>JNP1K5L-V5<\/td><td>450 V \/ 150\u2013400 V<\/td><td>15 A<\/td><td>1.5 \/ 1.5 kW<\/td><td>11 \/ 7 A<\/td><\/tr><tr><td>JNP2K2L-SE-V5<\/td><td>450 V \/ 150\u2013400 V<\/td><td>20 A<\/td><td>1.5 \/ 2.2 kW<\/td><td>13 \/ 11 A<\/td><\/tr><tr><td>JNP2K2L-V5<\/td><td>480 V \/ 200\u2013450 V<\/td><td>15 A<\/td><td>2.2 \/ 2.2 kW<\/td><td>15 \/ 11 A<\/td><\/tr><tr><td>JNP3KL-V5<\/td><td>480 V \/ 200\u2013450 V<\/td><td>30 A<\/td><td>2.2 \/ 3 kW<\/td><td>16 \/ 14 A<\/td><\/tr><tr><td>JNP3K7L-V5<\/td><td>480 V \/ 200\u2013450 V<\/td><td>30 A<\/td><td>2.2 \/ 3.7 kW<\/td><td>17 \/ 17 A<\/td><\/tr><tr><td>JNP4KL-V5<\/td><td>480 V \/ 200\u2013450 V<\/td><td>30 A<\/td><td>2.2 \/ 4 kW<\/td><td>18 \/ 20 A<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p>The 1PH and 3PH values describe the phase of the motor connected to the output. The auxiliary AC input published for the series is single-phase. Select the model from the motor nameplate, current, phase, and required margin, not from the commercial power rating alone.<\/p>\n\n\n<h2 class=\"wp-block-heading\" id=\"specifications-communes\">Published Common Specifications<\/h2>\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>Field<\/th><th>Published Value<\/th><th>Interpretation<\/th><\/tr><tr><td>MPPT Tracking<\/td><td>&gt; 99 %<\/td><td>Published MPPT tracking efficiency, distinct from inverter conversion efficiency<\/td><\/tr><tr><td>Number of PV Strings<\/td><td>1<\/td><td>One published input\/string; confirm connectors and permissible current<\/td><\/tr><tr><td>AC Input<\/td><td>198\u2013265 V AC for the first five models; 198\u2013264 V AC for the remaining four, 1PH<\/td><td>50\/60 Hz \u00b13 %<\/td><\/tr><tr><td>Motor Output<\/td><td>220\/230 V AC, 1PH or 3PH by model<\/td><td>Variable frequency 0\u201350\/60 Hz<\/td><\/tr><tr><td>Ingress Protection Rating<\/td><td>IP65<\/td><td>Follow the cable-gland, connection, and installation instructions<\/td><\/tr><tr><td>Published Temperature<\/td><td>\u221225 to 60 \u00b0C<\/td><td>Available power may depend on temperature<\/td><\/tr><tr><td>Cooling<\/td><td>Natural convection<\/td><td>Maintain airflow clearances<\/td><\/tr><tr><td>Display<\/td><td>LED\/LCD<\/td><td>Confirm the version by model and quotation<\/td><\/tr><tr><td>Communication<\/td><td>RS485; optional GPRS\/Bluetooth without LCD<\/td><td>Confirm options and protocol<\/td><\/tr><tr><td>Elevation<\/td><td>3,000 m<\/td><td>Published derating above 3,000 m<\/td><\/tr><tr><td>Published Noise<\/td><td>&lt; 50 dB<\/td><td>Measurement condition not stated<\/td><\/tr><tr><td>Dimensions \/ Weight<\/td><td>265 \u00d7 150 \u00d7 330 mm \/ 6.5 kg<\/td><td>Published common values for the series<\/td><\/tr><tr><td>Published Compliance<\/td><td>EN 50178 ; IEC\/EN 62109-1 ; IEC 61800<\/td><td>References declared on the product page<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<h2 class=\"wp-block-heading\" id=\"fonctionnement-hybride\">Solar, Grid, or Generator Operation<\/h2>\n\n\n<p>The term \u201chybrid\u201d indicates that solar power and an auxiliary AC input can be used. It does not by itself define source priority, combining, transition, generator limits, or backfeed protection. These parameters must be defined during commissioning. The quotation must state whether the AC input comes from the grid or a generator, its voltage and frequency, protection, and the selected priority mode.<\/p>\n\n\n<h2 class=\"wp-block-heading\" id=\"dimensionnement-pv\">PV Array Sizing<\/h2>\n\n\n<ul class=\"wp-block-list\"><li>keep the operating string voltage within the model\u2019s MPPT range;<\/li><li>verify that cold-weather open-circuit voltage remains below 450 or 480 V DC, depending on the model;<\/li><li>do not exceed the published maximum PV current;<\/li><li>account for temperature, shade, module tolerances, and cable lengths;<\/li><li>provide suitable isolation, surge protection, earthing, and connectors.<\/li><\/ul>\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-pompe\">Information Required to Select the Pump<\/h2>\n\n\n<p>Provide the pump brand and model, motor nameplate, phase, voltage, current, power, frequency, total dynamic head, required flow, and borehole or tank depth. Add cable distance, level or dry-run sensor type, installation location, and availability of the grid or a generator.<\/p>\n\n\n<p>The inverter does not size the hydraulic system. The pump, pipework, friction losses, flow, head, and daily volume must be consistent before selecting the electrical model and PV array.<\/p>\n\n\n<h2 class=\"wp-block-heading\" id=\"installation\">Installation and Commissioning<\/h2>\n\n\n<ul class=\"wp-block-list\"><li>install the unit with clearances and cable glands appropriate for IP65;<\/li><li>separate PV, AC-input, motor, control, and communication cables correctly;<\/li><li>configure motor limits, ramp, frequency, sensors, and source priority;<\/li><li>test rotation direction, flow, dry-run\/level protection, and emergency stop;<\/li><li>record the model, settings, measurements, and wiring diagram provided to the customer.<\/li><\/ul>\n\n\n<h2 class=\"wp-block-heading\" id=\"prix-indicatif-au-gabon\">Estimated Price in Gabon<\/h2>\n\n\n<p><strong>250,000 to 700,000 XAF<\/strong>, depending on model, power, communication options, connections, and protection. This range covers the product group and does not represent two fixed offers. The quotation identifies the exact model, accessories, delivery, installation, testing, inclusions, exclusions, and validity period.<\/p>\n\n\n<h2 class=\"wp-block-heading\" id=\"demander-un-devis\">Request a Quote<\/h2>\n\n\n<p>Provide the motor nameplate and hydraulic data to receive a selection from the nine models. <a href=\"#request-a-quote\">Request a quote for the JNP-V5 series<\/a> or <a href=\"https:\/\/wow2000.com\/en\/contact\/\">contact WOW2000<\/a> to confirm the inverter, PV array, protection, and commissioning scope.<\/p>","protected":false},"excerpt":{"rendered":"<p>S\u00e9rie JNP-V5 pour pompes solaires de 0,55 \u00e0 4 kW La s\u00e9rie JNP-V5 regroupe neuf onduleurs destin\u00e9s \u00e0 l\u2019entra\u00eenement de pompes \u00e0 courant alternatif \u00e0 partir d\u2019un champ photovolta\u00efque, avec une entr\u00e9e secteur ou groupe \u00e9lectrog\u00e8ne disponible selon la configuration. La gamme couvre des moteurs de 0,55 \u00e0 4 kW. Le choix d\u00e9pend de la [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1584,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"product_cat":[24],"product_tag":[],"class_list":["post-1359","wpkj_product","type-wpkj_product","status-publish","has-post-thumbnail","hentry","product_cat-ac"],"blocksy_meta":[],"acf":{"wpkj_product_gallery":[1584],"_product_excerpt":"<strong>Onduleur de pompe solaire hybride<\/strong>\u00a0<strong>Pour l'irrigation des petits champs<\/strong>\r\n\r\n<strong>Utilisation de l'\u00e9nergie solaire<\/strong>:Le syst\u00e8me convertit efficacement l\u2019\u00e9nergie solaire en \u00e9nergie pour alimenter les pompes \u00e0 eau, offrant ainsi une solution d\u2019approvisionnement en eau durable et \u00e9cologique, en particulier dans les zones recul\u00e9es ou hors r\u00e9seau.\r\n\r\n<strong>Haute efficacit\u00e9<\/strong>:L'onduleur assure une conversion optimale de l'\u00e9nergie des panneaux solaires, maximisant les performances de pompage tout en minimisant les pertes d'\u00e9nergie, ce qui conduit \u00e0 une meilleure efficacit\u00e9 globale.\r\n\r\n<strong>MPPT automatique (suivi du point de puissance maximale)<\/strong>:Dispose de la technologie MPPT qui ajuste dynamiquement le point de fonctionnement du panneau solaire, garantissant que le syst\u00e8me fonctionne toujours \u00e0 une puissance de sortie maximale, quelles que soient les conditions changeantes d'ensoleillement.","post_download_file":""},"_links":{"self":[{"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/wpkj_product\/1359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/wpkj_product"}],"about":[{"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/types\/wpkj_product"}],"author":[{"embeddable":true,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":5,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/wpkj_product\/1359\/revisions"}],"predecessor-version":[{"id":3767,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/wpkj_product\/1359\/revisions\/3767"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/media\/1584"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/media\/1584"}],"wp:attachment":[{"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/media?parent=1359"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/product_cat?post=1359"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wow2000.com\/en\/wp-json\/wp\/v2\/product_tag?post=1359"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}